 Part No: CMT-1603 Description: piezo audio transducer
Date: 9/19/2006 Unit: mm Page No: 1 of 6
Specifications
Operating voltage Current consumption Sound pressure level Electrostatic capacity Operating tempurature Storage tempurature Dimensions Weight Material Terminal RoHS 25 Vp-p max. 3 mA max. at 3 Vp-p, square wave, 4.0 KHz 70 db min. at 10 cm / 3 Vp-p, square wave, 4.0 KHz 14,000 pF 30% at 1 KHz / 1 V -30 ~ +70 C -40 ~ +85 C L16.0 x W16.0 x H2.6 mm 0.96 g max. LCB (White) + PCB (FR4) Pin type (Sn Plating) yes
Appearance Drawing
Tolerance: 0.2
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Part No: CMT-1603 Description: piezo audio transducer
Date: 9/19/2006 Unit: mm Page No: 2 of 6
Typical Frequency Response Curve
Measurement Method
S.P.L. Measuring Circuit Input Signal: 3 V p-p, 4.0 KHz, Square Wave Mic: RION UC 30 S.G.: Hewlett Packard 33120A Function Generator or equivalent
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Part No: CMT-1603 Description: piezo audio transducer
Date: 9/19/2006 Unit: mm Page No: 3 of 6
Mechanical Characteristics
Item Solderability Evaluation Standard Test Condition 95% of the surface of the lead Lead terminals are immersed in rosin for pads should be covered with 5 seconds and then immersed in solder bath solder. of 270 5C for 2 0.5 seconds. 1) IR Reflow Pre-heating conditions should be 150~200C for 60 to 180 seconds. Ascending time up to 245C should be longer than 55 seconds. Heating conditions should be within 20 to 40 seconds at 245C min. Peak temperature should be lower than 255C. The transducer should be measured after 1 hour in normal No interference in operation. conditions. 2) Soldering Iron A soldering iron of 2705C should be placed 0.5mm away from the electrode of the transducer. Melted solder should be applied to the electrode for 31 seconds. The transducer should be measured after 4 hours in normal conditions. For 10 seconds, the force of 9.8N (1.0kg) is applied to each terminal in axial direction. The transducer should be subjected to a vibration cycle of 10 to 55 Hz band of vibration frequency for a period of 1 minute. Total peak amplitude should be 1.5mm. The vibration test should consist of 2 hours per axis in each axial direction (X, Y, Z) for a total of 6 hours.
Soldering Heat Resistance
Terminal Mechanical Strength Vibration
No damage or cutting off. After the test, the part should meet specifications without any damage in appearance or performance except for SPL. The SPL should be within 10dB compared with the initial measurement.
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Part No: CMT-1603 Description: piezo audio transducer
Date: 9/19/2006 Unit: mm Page No: 4 of 6
Environment Test
Item High temp. test Low temp. test Humidity test Temp. cycle test Test Condition After being placed in a chamber at +85C for 240 hours. After being placed in a chamber at -40C for 240 hours. After being placed in a chamber at +40C and 905% relative humidity for 240 hours. The part shall be subjected to 5 cycles. One cycle will consist of: Evaluation Standard
The transducer should be measured after being placed at +25C for 4 hours. The value of the oscillation frequency/current consumption should be 10% compared to the initial measurements. The SPL should be within 10dB compared to the initial measurements.
Reliability Test
Item Operating (Life Test) Test Condition 1. Continuous life test: The part will be subjected to 48 hours of continuous operation at +55C with rated voltage applied. 2. Intermittent life test: A duty cycle of 1 minute on, 1 minute off, a minimum of 5,000 times at room temp (+25 2C) with rated voltage applied. Evaluation Standard The transducer will be measured after being placed at +25C for 4 hours. The value of the oscillation frequency/current consumption should be 10% compared to the initial measurements. The SPL should be within 10dB compared to the initial measurements.
Test Conditions
Standard Test Condition Judgement Test Condition a) Tempurature: +5 ~ +35C a) Tempurature: +25 2C b) Humidity: 45 - 85% b) Humidity: 60 - 70% c) Pressure: 860-1060 mbar c) Pressure: 860-1060 mbar
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Part No: CMT-1603 Description: piezo audio transducer
Date: 9/19/2006 Unit: mm Page No: 5 of 6
Recommended Temperature Profile for Reflow Oven
Note: 255C is less than 20 seconds, but only pass the lead free reflow once
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062
Part No: CMT-1603 Description: piezo audio transducer
Date: 9/19/2006 Unit: mm Page No: 6 of 6
Packaging
Phone: 800.275.4899
Fax: 503.612.2381
www.cui.com
20050 SW 112th Ave.
Tualatin, OR 97062


▲Up To Search▲   

 
Price & Availability of CMT-1603

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X